CLB-123-12C1N-R-A/12 [Carling Technologies]

Thermal Circuit Breaker,;
CLB-123-12C1N-R-A/12
型号: CLB-123-12C1N-R-A/12
厂家: Carling Technologies    Carling Technologies
描述:

Thermal Circuit Breaker,

电路保护
文件: 总5页 (文件大小:1019K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CLB-Series  
CLB-Series  
THERMAL CIRCUIT BREAKERS  
The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers designed to protect  
equipment. Utilizing simple, precision design with few moving parts, these breakers offer cost effective,  
extremely reliable circuit protection with high resistance against shock and vibration.  
Resources:  
Configure a Complete Part  
Download CAD & Sales Drawing  
Product Highlights:  
•ꢀ Ratingsꢀfromꢀ3-60A,ꢀ125,ꢀ250VAC,ꢀ32VDC  
•ꢀ 2500ꢀVAC/1ꢀminute  
•ꢀ 60°CꢀMaxꢀOperatingꢀTemperature  
•ꢀ 2500Aꢀ@ꢀ32VDCꢀInterruptingꢀCapacity  
•ꢀ 100MꢀohmsꢀInsulationꢀResistance  
•ꢀ Voltageꢀdropꢀ<0.25ꢀV  
•ꢀ UL,ꢀcUL,ꢀCSA,ꢀTUV,ꢀCE  
•ꢀ UL1500/ISO8846ꢀforꢀignitionꢀprotection/marine  
Applications:  
•ꢀ HouseholdꢀAppliances  
•ꢀ On/Off-Highway  
•ꢀ Marine  
•ꢀ PowerꢀStrips  
•ꢀ MedicalꢀEquipment  
•ꢀ AudioꢀVisualꢀEquipment  
•ꢀ PowerꢀSupplies  
•ꢀ ROHSꢀComplaint  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Email: sales@carlingtech.com  
Application Support: team2@carlingtech.com  
Phone: 860.793.9281 Fax: 860.793.9231  
www.carlingtech.com  
|
CLB-Series - Ordering Scheme  
2
CLB 10 3 12 C 3 B B A / 10  
5
6
7
8
9
10  
Button  
Marking  
1
2
3
4
Bushing  
Type  
Mounting Indicator  
Nut Plate  
Button  
Terminal  
Series  
Rating  
Voltage  
Mounting  
Hole  
1 SERIES  
CLB  
3 VOLTAGE  
3
125-250VAC/ 32 VDC  
2 RATING  
4 MOUNTING HOLE  
1
2
3
11  
12  
00  
M11  
03  
04  
05  
06  
07  
08  
10  
12  
13  
3 amps  
15  
18  
20  
25  
30  
35  
40  
50  
60  
15 amps  
18 amps  
20 amps  
25 amps  
30 amps  
35 amps  
40 amps  
50 amps  
60 amps  
M12  
4 amps  
5 amps  
6 amps  
7 amps  
8 amps  
10 amps  
12 amps  
13 amps  
Snap In  
Style  
4
27  
3/8” 27  
UNS  
12  
12  
5 BUSHING  
METAL  
6
A
B
J
Type A  
Type B  
Type J  
16  
8
PLASTIC  
5
7
8
C
D
E
Type C  
Type D  
Type E  
9
6 MOUNTING NUT  
N
1
2
3
4
5
6
7
8
None  
Type 1  
Type 2  
Type 3  
Type 4  
Type 5  
Type 6  
Type 7  
Type 8  
17  
4, 14  
4
4
NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings E & J only); Type 3 nut includes molded in “PRESS TO RESET” marking.  
9
Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified.  
Embossed  
Silver Printing  
On Black  
7 INDICATOR PLATE  
(ALUMINUM)  
N
A
B
None  
1
2
3
4
5
6
Used with bushing A or B only.  
Used with bushing A or C only.  
Used with bushing D only.  
11 Terminals are .040 [1.0] thickness for ratings  
greater than 35 amps. Terminals are .315 [0.8]  
thickness is for ratings less than 35 amps.  
12 Available only with 10-24 unc. screw terms.  
(select type F, G, H, J only.) UL, CUL only.  
Embossed  
Silver Printing  
on Black  
.887  
.887  
[22.5]  
.016  
[.4]  
.016  
[.4]  
[22.5]  
Used with bushing E & J only.  
Used with M12 mounting hole only.  
All indicator plates are marked  
“Suppl. Prot. press to reset”.  
Used with M11 and M12 mounting 13 Amp rating must match button marking (ex: “20”  
hole only.  
Used with mounting hole 00 only.  
Used with 27 mounting hole only.  
All hardware available separately.  
will be marked on the button of the breaker)  
14 Thickness is 3.0 mm, .118 in.  
15 Screw terminals are 8-32 UNC  
16 Used with M11 mounting hole only.  
17 Includes molded in “PRESS TO RESET” marking.  
7
8
9
10 Greater than 35 amp rating must  
use solder joint to connect wire to  
non-screw type terminals.  
8 BUTTON  
B
Black  
R
Red  
W
White  
10,11,15  
9 TERMINAL  
A
B
C
D
E
F
G
H
J
Type A  
Type B  
Type C  
Type D  
Type E  
Type F  
Type G  
Type H  
Type J  
Type K  
Type R  
R
without screw  
K
R
13  
line  
load  
10 BUTTON MARKING (IF BLANK, NO MARKING)  
Button Marking Orientation:  
20  
03  
04  
05  
3 amp  
4 amp  
5 amp  
06  
07  
08  
6 amp  
7 amp  
8 amp  
10  
12  
13  
10 amp  
12 amp  
13 amp  
15  
18  
20  
15 amp  
18 amp  
20 amp  
25  
30  
35  
25 amp  
30 amp  
35 amp  
40  
50  
60  
40 amp  
50 amp  
60 amp  
*Manufacturer reserves the right to change product specification without prior notice.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
3
CLB-Series - Dimensional Specifications, Time Delay  
Dimensional Specifications: in. [mm]  
3-40A Construction  
50 & 60A Construction  
Time Delay  
Trip Time in Seconds  
Overload  
Trip Time  
No Trip  
Trip in 1 hr  
4.0 ~ 40 sec.  
0.9 ~ 8.0 sec.  
Time Trip Factor 1  
-10 °C x 1.70  
Time Trip Factor 1  
30 °C x 0.90  
35 °C x 0.85  
40 °C x 0.80  
45 °C x 0.75  
50 °C x 0.70  
55 °C x 0.65  
60 °C x 0.60  
100%  
150%  
200%  
300%  
-5 °C  
0 °C  
5 °C  
x 1.60  
x 1.50  
x 1.40  
Notes:  
1.  
Trip Time factor is a  
guideline that indicates  
ambient temperature  
effect on trip times at  
various overload values.  
10 °C x 1.30  
15 °C x 1.20  
20 °C x 1.10  
25 °C x 1.00  
400% 0.42 ~ 5.0 sec.  
500% 0.25 ~ 3.0 sec.  
600% 0.01 ~ 1.8 sec.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
Sales Representatives, Distributors & Company Profile  
4
Authorized Sales Representatives and Distributors  
Click on a region of the map below to find your local representatives and distributors or visit  
www.carlingtech.com/findarep.  
CANADA  
EUROPE  
USA  
MIDDLE  
EAST  
MEXICO  
AFRICA  
ASIA-PACIFIC  
OCEANIA  
SOUTH  
AMERICA  
About Carling  
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches  
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power  
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,  
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical  
components, they engineer powerful solutions! To learn more about Carling please visit  
www.carlingtech.com/company-profile.  
To view all of Carling’s environmental, quality, health & safety certifications please visit  
www.carlingtech.com/environmental-certifications  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
Worldwide Headquarters  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Phone: 860.793.9281 Fax: 860.793.9231  
@
Email: sales carlingtech.com  
@
Northern Region Sales Office: nrsm carlingtech.com  
@
Southeast Region Sales Office: sersm carlingtech.com  
@
Midwest Region Sales Office: mrsm carlingtech.com  
@
West Region Sales Office: wrsm carlingtech.com  
@
Latin America Sales Office: larsm carlingtech.com  
Asia-Pacific Headquarters  
Carling Technologies, Asia-Pacific Ltd.,  
Suite 1607, 16/F Tower 2, The Gateway,  
Harbour City, 25 Canton Road,  
Tsimshatsui, Kowloon, Hong Kong  
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332  
@
Email: sales carlingtech.com.hk  
@
Shenzhen, China: shenzhen carlingtech.com  
@
Shanghai, China: shanghai carlingtech.com  
@
Pune, India: india carlingtech.com  
@
Kaohsiung, Taiwan: taiwan carlingtech.com  
@
Yokohama, Japan: japan carlingtech.com  
|
|
Europe Middle East Africa Headquarters  
Carling Technologies LTD  
4 Airport Business Park, Exeter Airport,  
Clyst Honiton, Exeter, Devon, EX5 2UL, UK  
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477  
@
Email: ltd.sales carlingtech.com  
@
Germany: gmbh carlingtech.com  
@
France: sas carlingtech.com  
www.carlingtech.com  
REV_07_2019  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications